Abstract

Single longitudinal mode (SLM) selection in a 10-atm CO(2) laser is reported. Experiments have been performed with cw injection of 1 mW/cm(2) or pulsed injection of 1 mJ/cm(2) (in 50 ns) around CO(2) line centers. A simple analytical formula of the minimum intensity required for injection of a frequency nu has been obtained. It gives the dependence vs the two most important parameters: (1) the detuning nu-nu to the center nu of the net gain curve, (2) the detuning deltanu(Kappa) to the nearest longitudinal mode of the cavity. The comparison with experimental results published on TEA lasers is very successful. The application of the formula shows the possibility of SLM selection continuously tunable in a high pressure CO(2) laser with <1 mW/cm(2) if a grating is incorporated in the cavity, and with a pulsed source of 1 kW/cm(2) without any selective element. The actual sources suitable for this purpose are reviewed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.