Abstract

Paclitaxel-coated peripheral devices have been associated with increased mortality, yet this harm signal has not been replicated outside of meta-analyses of small trials. To provide a longitudinal assessment of the safety of femoropopliteal endovascular treatment with peripheral drug-coated devices (DCDs) among Medicare beneficiaries. SAFE-PAD (Safety Assessment of Femoropopliteal Endovascular Treatment With Paclitaxel-Coated Devices) was a retrospective cohort study designed with the US Food and Drug Administration to evaluate the noninferiority of mortality between DCDs and non-drug-coated devices (NDCDs) for femoropopliteal revascularization performed in 2978 inpatient and outpatient facilities in the US from April 1, 2015, through December 31, 2018. Evaluation of the primary outcome was assessed through May 31, 2020. Participants were Medicare fee-for-service beneficiaries 66 years and older with 1 or more years of enrollment prior to femoropopliteal revascularization. Prespecified subgroups included low-risk cohorts, procedure location, disease severity, and device type. Inverse probability weighting was used to account for imbalances of observed characteristics. Sensitivity analyses were used to evaluate the potential influence of unmeasured confounding. Treatment with DCDs vs NDCDs as determined by claims codes during the index procedure. The primary outcome was all-cause mortality. Secondary outcomes included repeated hospitalization, repeated lower extremity revascularization, and lower extremity amputation. Falsification end points were acute myocardial infarction, congestive heart failure, and pneumonia. Of 168 553 patients, 70 584 (41.9%) were treated with a DCD. The mean (SD) age was 77.0 (7.6) years, 75 744 (44.9%) were female, 136 916 of 167 197 (81.9%) were White individuals, 85 880 of 168 553 (51.0%) had diabetes, 82 554 of 168 553 (49.0%) used tobacco, 78 665 of 168 553 (45.7%) had critical limb ischemia (CLI), and 13 296 of 168 553 (7.9%) had a prior amputation. Median follow-up was 2.72 years (interquartile range, 0.87-3.77; longest, 5.16 years). After weighting, the cumulative incidence of all-cause mortality was 53.8% with DCDs and 55.1% with NDCDs (hazard ratio [HR], 0.95; 95% CI, 0.94-0.97; noninferiority P < .001). Cox regression and instrumental variable analyses were consistent with the primary findings. No harm associated with DCDs was observed among subgroups, including those treated with stents (HR, 0.97; 95% CI, 0.95-1.00) or balloons (HR, 0.94; 95% CI, 0.92-0.96), with or without CLI (CLI: HR, 0.95; 95% CI, 0.93-0.97; non-CLI: HR, 0.97; 95% CI, 0.95-0.99), and those within the lowest quartile of total comorbidities (HR, 0.95; 95% CI, 0.92-0.99). In this initial report from the SAFE-PAD cohort study, DCDs were found to be noninferior to NCDCs in respect to mortality through a median follow-up of 2.72 years. This finding remained robust in sensitivity analyses and was consistent across prespecified subgroups.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.