Abstract

The purpose of this study was to investigate the long-term stability of auditory N1 sources using low-resolution electromagnetic tomography (LORETA). Data collected from 72 electrodes in ten young adult female participants were analyzed. For each participant, N1 peak amplitude and latency values at Cz (referred to M2) were compared for right, left, and bilateral stimulation across three separate recording sessions. Further, sources calculated by LORETA were analyzed in three regions of interest: right temporal, left temporal, and frontal. Peak amplitude and latency measurements were stable across session and ear of stimulation. Three-way RM-ANOVAs revealed relatively stable source amplitudes and stable three-dimensional locations of the sources in each region of interest with shifts of up to 2 cm around the mean locations. The 2 cm variability may be attributable both to normal hemispheric asymmetries and electrode placement variability. These results suggest that N1 scalp activity and its underlying sources are stable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.