Abstract

Between 1982 and 1989, 46 patients had insertion of an Angelchik prosthesis for gastro-oesophageal reflux. Eleven patients (24 per cent) subsequently had the prosthesis removed, all but one for intractable dysphagia. Thirty-six of the original patients were followed by questionnaire, and 32 of these had a barium marshmallow swallow investigation. A high proportion of patients (20 of 26) with a prosthesis in situ had symptoms of dysphagia. On objective evaluation by marshmallow swallow, the transit time was significantly slower than that of an age-matched control group (P < 0.01), but showed no significant deterioration with time compared with previous postinsertion studies. The Angelchik prosthesis causes long-term dysphagia in a high proportion of patients, severe enough in one-quarter to necessitate its removal. Its continued use cannot, therefore, be recommended.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.