Abstract

The purpose of this study was to present a lock-in-amplifier model for analyzing the behavior of signal harmonics in magnetic particle imaging (MPI) and some simulation results based on this model. In the lock-in-amplifier model, the signal induced by magnetic nanoparticles (MNPs) in a receiving coil was multiplied with a reference signal, and was then fed through a low-pass filter to extract the DC component of the signal (output signal). The MPI signal was defined as the mean of the absolute value of the output signal. The magnetization and particle size distribution of MNPs were assumed to obey the Langevin theory of paramagnetism and a log-normal distribution, respectively, and the strength of the selection magnetic field (SMF) in MPI was assumed to be given by the product of the gradient strength of the SMF and the distance from the field-free region (x). In addition, Gaussian noise was added to the signal induced by MNPs using normally-distributed random numbers. The relationships between the MPI signal and x were calculated for the odd- and even-numbered harmonics and were investigated for various time constants of the low-pass filter used in the lock-in amplifier and particle sizes and their distributions of MNPs. We found that the behavior of the MPI signal largely depended on the time constant of the low-pass filter and the particle size of MNPs. This lock-in-amplifier model will be useful for better understanding, optimizing, and developing MPI, and for designing MNPs appropriate for MPI.

Highlights

  • In 2005, a new imaging method called magnetic particle imaging (MPI) was introduced [1]

  • The purpose of this study was to present a lock-in-amplifier model for analyzing the behavior of signal harmonics in magnetic particle imaging (MPI) and some simulation results based on this model

  • We previously investigated the behavior of signal harmonics in MPI by experimental and simulation studies, and reported that it largely depended on the strength of the drive and selection magnetic fields and the particle size distribution of magnetic nanoparticles (MNPs) [3]

Read more

Summary

Introduction

In 2005, a new imaging method called magnetic particle imaging (MPI) was introduced [1]. MPI utilizes the nonlinear response of MNPs to detect their presence in an alternating magnetic field called the drive magnetic field. Due to the nonlinear response of the MNPs to an applied drive magnetic field, the signals generated by the MNPs in a receiving coil contain the excitation frequency and the harmonics of this frequency. These harmonics are used for image reconstruction in MPI [1]. It is known that the magnetization response of MNPs depends on the magnetic properties of MNPs and on the particle size and distribution of MNPs [2]

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.