Abstract

The load carrying capacity of damaged prestressed concrete railway sleepers has been investigated in order to obtain information about how the cracking influences the remaining load carrying capacity compared with an uncracked sleeper. The following tests have been performed: bending capacity of the midsection, the rail section, horizontal load capacity of the fastener, control of the concrete properties and fatigue capacity in bending of the rail section. A visual inspection and classification of the damages are also presented. The test results have been compared with calculations according to the Swedish railway code for sleepers and show that railway sleepers are quite robust. Small cracks do not seem to influence the load carrying capacity and it is first when the cracking is very severe that the load carrying capacity is reduced significantly. [doi: 10.1680/stco.2007.00024]

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.