Abstract

This paper reports the effect of values of starting and synchronisation (running) capacitors on the line-start performance of a single-phase cage-rotor synchronous reluctance motor. The d-q rotor reference frame dynamic equations were used to select the values of capacitors best suited for starting and running and it is shown that for a near-instantaneous starting, the capacitances should be varied (within the selected peaks) in line with the machine speed error. One single three-terminal capacitor device controlled by speed error signal is found to be very useful in realising a faster acceleration than obtainable with conventional and other known methods. Peak torque pulsations and current drawn by the main winding were found to be reduced, suggesting a more efficient motor drive performance. Simulated and experimental results bear a resemblance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.