Abstract

In this paper, limit cycle frequency, pulse width and stability analysis are examined using different methods for relay feedback nonlinear control systems with integer or fractional order plant transfer functions. The describing function (DF), A loci, a time domain method formulated in state space notation and Matlab/Simulink simulations are used for the analysis. Comparisons of the results of using these methods are given in several examples. In addition, the work has been extended to fractional order systems with time delay. Programs have been developed in the Matlab environment for all the theoretical methods. In particular, Matlab programs have been written to obtain a graphical solution for the A loci method, which can precisely calculate the limit cycle frequency. The developed solution methods are shown in various examples. The major contribution is to look at finding limit cycles for relay feedback systems having plants with a fractional order transfer function (FOTF). However, en route to this goal new assessments of limit cycle stability have been done for a rational plant transfer function plus a time delay.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.