Abstract

Lidocaine (L) levels were measured by gas chromatography (GC) and a new technique of direct measurement by enzyme immunoassay (EMIT) in 50 consecutive patients admitted to the Coronary Care Unit who received L. There was no significant difference between the levels by the two techniques. There was eradication of most ventricular arrhythmias in 78% of patients, partial effectiveness in 16%, and no improvement in 6%. Toxicity was mainly mild central nervous system effects, noted in 26 of the 50 patients. All six patients with serum L above 5.9 microgram/ml had signs of toxicity. EMIT was found to be accurate and much faster than the traditional GC method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.