Abstract

IntroductionThe purpose of the present study was to investigate microcirculatory blood flow in patients with septic shock treated with levosimendan as compared to an active comparator drug (i.e. dobutamine). The primary end point was a difference of ≥ 20% in the microvascular flow index of small vessels (MFIs) among groups.MethodsThe study was designed as a prospective, randomized, double-blind clinical trial and performed in a multidisciplinary intensive care unit. After achieving normovolemia and a mean arterial pressure of at least 65 mmHg, 40 septic shock patients were randomized to receive either levosimendan 0.2 μg·kg-1·min-1 (n = 20) or an active comparator (dobutamine 5 μg·kg-1·min-1; control; n = 20) for 24 hours. Sublingual microcirculatory blood flow of small and medium vessels was assessed by sidestream dark-field imaging. Microcirculatory variables and data from right heart catheterization were obtained at baseline and 24 hours after randomization. Baseline and demographic data were compared by means of Mann-Whitney rank sum test or chi-square test, as appropriate. Microvascular and hemodynamic variables were analyzed using the Mann-Whitney rank sum test.ResultsMicrocirculatory flow indices of small and medium vessels increased over time and were significantly higher in the levosimendan group as compared to the control group (24 hrs: MFIm 3.0 (3.0; 3.0) vs. 2.9 (2.8; 3.0); P = .02; MFIs 2.9 (2.9; 3.0) vs. 2.7 (2.3; 2.8); P < .001). The relative increase of perfused vessel density vs. baseline was significantly higher in the levosimendan group than in the control group (dMFIm 10 (3; 23)% vs. 0 (-1; 9)%; P = .007; dMFIs 47 (26; 83)% vs. 10 (-3; 27); P < .001). In addition, the heterogeneity index decreased only in the levosimendan group (dHI -93 (-100; -84)% vs. 0 (-78; 57)%; P < .001). There was no statistically significant correlation between systemic and microcirculatory flow variables within each group (each P > .05).ConclusionsCompared to a standard dose of 5 μg·kg-1·min-1 of dobutamine, levosimendan at 0.2 μg·kg-1·min-1 improved sublingual microcirculatory blood flow in patients with septic shock, as reflected by changes in microcirculatory flow indices of small and medium vessels.Trial registrationNCT00800306.

Highlights

  • The purpose of the present study was to investigate microcirculatory blood flow in patients with septic shock treated with levosimendan as compared to an active comparator drug

  • We aimed at rejecting the null hypothesis that there is no difference in sublingual microvascular blood flow - as measured by sidestream dark-field (SDF) imaging [17] - in patients with fluid-resuscitated septic shock treated with levosimendan as compared with an active comparator drug

  • mixed-venous oxygen saturation (SvO2) and arterial pH tended to be higher whereas NE requirements tended to be lower in the levosimendan group (Table 2)

Read more

Summary

Introduction

The purpose of the present study was to investigate microcirculatory blood flow in patients with septic shock treated with levosimendan as compared to an active comparator drug (i.e. dobutamine). Microvascular dysfunction plays a pivotal role in the pathophysiology of septic shock and may occur even in the presence of normal systemic oxygen supply and mean arterial pressure [1]. The objective of the present randomized controlled, double-blinded clinical study was, to elucidate the effects of levosimendan on systemic and microvascular hemodynamics On this basis, we aimed at rejecting the null hypothesis that there is no difference in sublingual microvascular blood flow - as measured by sidestream dark-field (SDF) imaging [17] - in patients with fluid-resuscitated septic shock treated with levosimendan as compared with an active comparator drug (that is, dobutamine)

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.