Abstract

Legionella bacteria can colonise and proliferate in water systems in the built environment and can be spread by aerosol generation. If inhaled by a susceptible individual, this can lead to respiratory infections such as Legionnaires' Disease (LD), or the generally milder Pontiac fever. Evaporative cooling systems (ECS), including cooling towers, used in industrial processes to dissipate excessive heat are prone to contamination by Legionella. From these systems it is possible for contaminated aerosols to be dispersed over a wide area, potentially exposing workers on site, neighbouring workplaces or nearby members of the public. Analysis of reported data on outbreaks of LD in Great Britain, collated for a ten year period, identified 44 separate legionellosis outbreaks of which seven were attributed to ECS and were responsible for 229 infections and 10 fatalities. This prompted an examination of health and safety inspection records which revealed, over a five year period, 321 enforcement actions taken against failings in Legionella control, of which 31% were attributed to cooling towers. Based on this evidence, an intervention programme was undertaken by health and safety inspectors in which 1,906 sites with ECS were inspected. During these inspections, sites were rated against four topics that are used to demonstrate compliance with statutory requirements for Legionella control: Risk Assessment; Written Control Scheme; Implementation of Control Scheme; and Record Keeping. While there was compliance at the majority of sites, breaches of the legislation were found at 625 sites (33% of those inspected), leading to 409 Improvement Notices (compelling dutyholders to make improvements to health and safety breaches of law in a given timeframe) and 12 Prohibition Notices (compelling dutyholders to stop work until they have remedied breaches in health and safety law) being served at 229 sites (12.0% of those inspected). Data from the intervention programme was analysed to identify root causes of these breaches of legislation on Legionella control. The majority of Improvement Notices (53%) were issued for the 'lack of effective implementation of a Written Control Scheme', with 'Risk Assessment' and 'Written Control Scheme' both accounting for 23%. More detailed examination showed major problems to be lack of training; failure to maintain the cleanliness of cooling towers and the water within them; risk assessments either being absent or not up to date, i.e., no longer representing the risks present; and Written Control Schemes being absent or insufficiently detailed. This provides a valuable data resource for dutyholders, so that they can understand where they need to focus to achieve significant improvement in legal compliance and therefore reduce the risk of LD for employees and members of the public affected by their workplace, and valuable data for regulators to target future interventions aimed at improving dutyholder compliance leading to better protection of workers and members of the public.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.