Pump thrombosis (PT) is a dreaded complication after left ventricular assist device (LVAD) implantation. Problems with inflow cannula (IC) position may precipitate thrombus development. We sought to determine if IC position contributes to the development of PT. We conducted a retrospective review of 76 HeartMate II LVAD implants. The angle of the IC (AIC) to the horizontal plane was measured on chest x-rays. Patients who developed PT (PT group) were compared to the remaining patients (control group). The mean age at implantation was 56 ± 14 years, and 82% of the patients were male. Ten patients (13%) developed PT. Six (60%) required device exchange, and 4 (40%) were managed with anticoagulation and/or thrombolysis. The median AIC for all patients at implantation was 59° (range, 38°-98°; 25th-75th interquartile range, 50°-75°). In the PT group, the median AIC was larger at the time of PT diagnosis compared to implantation (70° vs 60°, P = 0.005). In the control group, the median AIC was also larger at follow-up compared to implantation (61° vs 58°, P < 0.001) although to a lesser degree than in the PT group. No difference was seen in the median AIC between the PT group and the control group at implantation (60° vs 58°, respectively; P = 0.668) or at follow-up (70° vs 61°, respectively; P = 0.309). However, the median AIC at follow-up in the PT group was significantly larger than the median AIC at implantation in the control group (70° vs 58°, respectively; P = 0.014). The HeartMate II LVAD IC position contributes to the development of PT. Regular monitoring of cannula position may help identify patients at risk for this problem.

Highlights

  • Pump thrombosis (PT) is a dreaded and occasionally lethal complication after left ventricular assist device (LVAD) placement

  • The patients in both groups were similar with regard to age, sex, body mass index, etiology of heart failure, indication for LVAD implantation, and duration of device support

  • While we could not demonstrate a significant difference in the angle of the IC (AIC) and the time of implantation between the 2 groups, the AIC was significantly larger in the PT group at the time of PT diagnosis compared to the control group at the time of implantation

Read more

Summary

Introduction

Pump thrombosis (PT) is a dreaded and occasionally lethal complication after left ventricular assist device (LVAD) placement. Pump thrombosis (PT) is a dreaded complication after left ventricular assist device (LVAD) implantation. In the PT group, the median AIC was larger at the time of PT diagnosis compared to implantation (70° vs 60°, P = 0.005). The median AIC was larger at follow-up compared to implantation (61° vs 58°, P < 0.001) to a lesser degree than in the PT group. No difference was seen in the median AIC between the PT group and the control group at implantation (60° vs 58°, respectively; P = 0.668) or at follow-up (70° vs 61°, respectively; P = 0.309). Conclusion: The HeartMate II LVAD IC position contributes to the development of PT. Regular monitoring of cannula position may help identify patients at risk for this problem

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.