Abstract
Bicuspid aortic valve (BAV), the most common congenital valve defect, is associated with increased risk of aortic dilation and related complications; however, current risk assessment is not effective. Most of BAV have three leaflets with a fusion between two of them of variable length. This study aimed to ascertain whether the extent of leaflet fusion (often called raphe) is related to aortic dilation and flow abnormalities in BAV with no significant valvular dysfunction. One hundred and twenty BAV patients with no significant valvular dysfunction or history of surgical repair or aortic valve replacement were consecutively and prospectively enrolled (September 2014-October 2018). Cardiac magnetic resonance protocol included a 4D flow sequence for haemodynamic assessment. Moreover, a stack of double-oblique cine images of the aortic valve were used to quantify fusion length (in systole) and leaflet length (diastole). Inter- and intra-observer reproducibility was tested in 30 randomly selected patients. Aortic valve leaflet fusion was measurable in 112 of 120 (93%) cases with good reproducibility (ICC = 0.826). Fusion length varied greatly (range: 2.3-15.4mm; mean: 7.8 ± 3.2mm). After correction for demographic and clinical conditions, fusion length was independently associated with diameter and z-score at the sinus of Valsalva (p = 0.002 and p = 0.002, respectively) and ascending aorta (p = 0.028 and p = 0.046). Fusion length was positively related to flow asymmetry, vortices and circumferential wall shear stress, thereby possibly providing a pathophysiological link with aortic dilation. Aortic valve fusion length is related to aortic dilation and flow abnormalities in BAV patients. • The length of the fusion between leaflets in non-dysfunctional bicuspid aortic valves varies substantially and can be reliably measured by cine CMR. • Aortic valve leaflet fusion length is independently related to aortic sinus and ascending aorta diameter. • Increased flow asymmetry, circumferential wall shear stress and presence of vortices are positively related to aortic valve leaflet fusion length.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.