Abstract

The release of diethylhexyl phthalate (DEHP) from flexible polyvinyl chloride containers into intravenous cyclosporine solutions was studied. Intravenous cyclosporine solution or solutions containing the vehicle Cremophor EL and alcohol in dextrose were prepared in an all-glass system and stored in polyvinyl chloride (PVC) bags. Four samples were obtained at different time intervals, and DEHP content was analyzed by gas chromatography. The amount of DEHP that was leached into solutions stored in the PVC bags increased as storage time increased. By 48 hours, nearly 33 mg of DEHP had leached into the solution. Intravenous cyclosporine solutions should be prepared in glass containers to minimize patient exposure to DEHP. If plastic bags are used for preparing cyclosporine injections, the injections must be used immediately after preparation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.