Abstract
The purpose of this work is to develop methodologies for the evaluation of LBLOCA in CANDU-NG reactors with the codes DONJON and DRAGON. CANDU-NG reactor differ from traditional CANDU reactors in being cooled by light water, using enriched fuel and burnable poisons, having significantly lesser quantity of heavy water moderator. The evaluation shows that methodology developed for CANDU-NG LBLOCA properly detects positive reactivity introduced in the core by initial voiding in checkerboard pattern, peaking at 143pcm. Such reactivity quickly becomes negative, however, bottoming at −804pcm and the reactor shuts down by itself without the intervention of any engineered system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.