Abstract

Purpose/objectiveAssess to what extent the use of automated treatment planning would have reduced organ-at-risk dose delivery observed in the randomized HYPRO trial for prostate cancer, and estimate related toxicity reductions. Investigate to what extent improved plan quality for hypofractionation scheme as achieved with automated planning can potentially reduce observed enhanced toxicity for the investigated hypofractionation scheme to levels observed for conventional fractionation scheme. Material/methodsFor 725 trial patients, VMAT plans were generated with an algorithm for automated multi-criterial plan generation (autoVMAT). All clinically delivered plans (CLINICAL), generated with commonly applied interactive trial-and-error planning were also available for the investigations. Analyses were based on dose-volume histograms (DVH) and predicted normal tissue complication probabilities (NTCP) for late gastrointestinal (GI) toxicity. ResultsCompared to CLINICAL, autoVMAT plans had similar or higher PTV coverage, while large and statistically significant OAR sparing was achieved. Mean doses in the rectum, anus and bladder were reduced by 7.8 ± 4.7 Gy, 7.9 ± 6.0 Gy and 4.2 ± 2.9 Gy, respectively (p < 0.001). NTCPs for late grade ≥2 GI toxicity, rectal bleeding and stool incontinence were reduced from 23.3 ± 9.1% to 19.7 ± 8.9%, from 9.7 ± 2.8% to 8.2 ± 2.8%, and from 16.8 ± 8.5% to 13.1 ± 7.2%, respectively (p < 0.001). Reductions in rectal bleeding NTCP were observed for all published Equivalent Uniform Dose volume parameters, n. AutoVMAT allowed hypofractionation with predicted toxicity similar to conventional fractionation with CLINICAL plans. ConclusionCompared to CLINICAL, autoVMAT had superior plan quality, with meaningful NTCP reductions for both conventional fractionation and hypofractionation schemes. AutoVMAT plans might reduce toxicity for hypofractionation to levels that were clinically observed (and accepted) for conventional fractionation. This may be relevant when considering clinical use of the investigated hypofractionation schedule with relatively high fraction dose (3.4 Gy).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.