Abstract
Laser-induced breakdown spectroscopy (LIBS) was carried out on twenty-three low to high alloy steel samples to quantify their concentrations of chromium, nickel, and manganese. LIBS spectral data were correlated to known concentrations of the samples and three calibration methods were compared. A standard LIBS calibration technique using peak area integration normalized by an internal standard was compared to peak area integration normalized by total light and the multivariate statistical technique of partial least squares. For the partial least squares analysis, the PLS-1 algorithm was used, where a predictive model is generated for each element separately. Partial least squares regression coefficients show that the algorithm correctly identifies the atomic emission peaks of interest for each of the elements. Predictive capabilities of each calibration approach were quantified by calculating the standard and relative errors of prediction. The performance of partial least squares is on par with using iron as an internal standard but has the key advantage that it can be applied to samples where the concentrations of all elements are unknown.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.