Abstract

The frequency of a DFB quantum cascade laser (QCL) emitting at 4.3 microm has been long-term stabilized to the Lamb-dip center of a CO2 ro-vibrational transition by means of first-derivative locking to the saturated absorption signal. Thanks to the non-linear sum-frequency generation (SFG) process with a fiber-amplified Nd:YAG laser, the QCL mid-infrared (IR) radiation has been linked to an optical frequency-comb synthesizer (OFCS) and its absolute frequency counted with a kHz-level precision and an overall uncertainty of 75 kHz.

Highlights

  • The most recent trace-gas sensing and frequency metrology applications are increasingly looking toward the mid-IR spectral region, known as the molecular “fingerprint” region, pushed by the presence of the fundamental ro-vibrational transitions of many simple molecules like CO2 and CH4 that are relevant for atmospheric implications.Difference-frequency generation (DFG) of tunable light has proven to be a suitable techniqueReceived 21 Apr 2008; revised 12 Jun 2008; accepted 20 Jun 2008; published 18 Jul 2008 21 July 2008 / Vol 16, No 15 / OPTICS EXPRESS 11638 for mid-IR trace-gas detection [1], high-resolution spectroscopy [2] and, after the introduction of optical frequency-comb synthesizer (OFCS) [3, 4], precise absolute frequency measurements [5, 6]

  • The frequency of a DFB quantum cascade laser (QCL) emitting at 4.3 μm has been long-term stabilized to the Lamb-dip center of a CO 2 ro-vibrational transition by means of first-derivative locking to the saturated absorption signal

  • Thanks to the non-linear sum-frequency generation (SFG) process with a fiber-amplified Nd:YAG laser, the QCL mid-infrared (IR) radiation has been linked to an optical frequency-comb synthesizer (OFCS) and its absolute frequency counted with a kHz-level precision and an overall uncertainty of 75 kHz

Read more

Summary

Introduction

The most recent trace-gas sensing and frequency metrology applications are increasingly looking toward the mid-IR spectral region, known as the molecular “fingerprint” region, pushed by the presence of the fundamental ro-vibrational transitions of many simple molecules like CO2 and CH4 that are relevant for atmospheric implications (greenhouse effect, pollution monitoring). The high versatility of these sources has allowed us to perform both sensitive detection on N2O and CH4 by frequency-modulation spectroscopy [23] and Doppler-limited comb-assisted absolute frequency measurements of CO 2 transitions [24]. These experiments pointed out the benefits coming from a frequency stabilization of the QCL: in particular, a higher precision in frequency measurements can be achieved by locking the laser to a narrow reference and averaging the counts over long timescales.

Sub-Doppler spectroscopy of CO2 with a QCL
Frequency locking to the Lamb dip
Absolute frequency measurements of the CO2 saturated transition
Findings
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.