Abstract

An investigation of the annoyance from the wind turbine noise, to which neighbors may be exposed, is carried out. The aim is to obtain dose-response relationships and to uncover if specific noise components (e.g. low-frequencies) are primary contributors to the annoyance. In the experiments, sounds recorded close to large wind turbines are filtered (and levels adjusted accordingly) to represent indoor and outdoor positions at the neighbors' dwellings and played back in the laboratory. Challenges relating to the recording and transformation of sounds are discussed. The exposure technique is a combination of an advanced low-frequency chamber that can reproduce the frequency range 2-250 Hz (with uniform distribution in the room) and additional loudspeakers for the higher frequencies. The listening test is a randomized design. The stimuli, of 10 minute duration, are presented at three levels and in combinations of filtered versions (low- and mid-frequency) such that the influence of low-frequency tonal components and level fluctuations is investigated. 25 subjects are exposed to the stimuli while reading a novel and afterwards they rate annoyance on a visual analog scale.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.