Abstract
The combination of a very brilliant X-ray source and state-ofthe-art X-ray optics opens the way to nano-focusing applications. Dynamically bent graded multilayers set in the KB-geometry are developed at the ESRF as an extremely efficient device to focus undulator radiation to spots below 100 nm [1]. The smallest 2D focus reached so far with this device is of the order of 80 nm in both directions. This has been achieved both on a long, coherent beamline and on a shorter beamline using the concept of a secondary source. The first mirror of the system, coated with a graded multilayer, plays both the role of vertical focusing device and monochromator, resulting in a very high flux (a few 10 11 photons/s) and medium monochromaticity (ΔE/E∼10p). Two different fields benefit particularly from the combination small focus / high flux: projection microscopy (magnified tomography) and X-ray fluorescence mapping. In projection microscopy the sample is set at a small distance (10-100 mm) downstream or upstream of the focus and a magnified Fresnel diffraction pattern is recorded on a medium resolution detector set at a large distance (several meters) from the focus. This approach allows to overcome the spatial resolution limit imposed by the detector in the parallel beam geometry. It was used to give direct evidence of nanometric invasion-like grain boundary penetration in the Al/Ga system [2]. For tomography, scans are acquired at different focussample distances. This yields variable magnifications, but also different effective propagation distances (∼equal to the focussample distance). The principal difficulties in this approach are related to the mirror imperfections and the pronounced refraction effects at the sample edges when going to sub-100 nm pixel sizes. Satisfactory results were however obtained in local tomography mode on aluminium alloys. A correction for mirror figure error and a phase retrieval method adapted to the imaging setup are incorporated in the tomograhic procedure [3]. In fluorescence imaging the sample is scanned through the focal plane while the spectrum of the emitted fluorescence is recorded with an energy dispersive detector. This rich probe, complementary to transmission imaging, provides element specific information and allows to image and quantify trace elements. The possibility to apply this method to the field of neurochemistry at the sub-cellular level has been demonstrated. Finally, the best one dimensional focus reached so far with reflective multilayer optics is 40 nm. The ultimate limits of this focusing approach will be discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Acta Crystallographica Section A Foundations of Crystallography
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.