Abstract

Hydrogen sulfide sorption activities of manganese oxide and Mn-Fe-Cu mixed oxide sorbents were examined in a fixed bed reactor. Sulfur retention capacity of Mn-O sorbent was found to be quite high at 600 °C both in the absence and presence of hydrogen gas (0.17 and 0.14 g S/g sorbent, respectively). This sorbent has a high porosity and a relatively high surface area. Best regeneration temperature of this sorbent was found as 700 °C, with a gas stream containing 6% oxygen in nitrogen. Mn-Fe-Cu mixed oxide sorbent had a lower sulfur retention capacity (0.07 g S/g sorbent). However, both of these sorbents gave quite high initial sorption rate constants, resulting very sharp breakthrough curves. Deactivation model was shown to give good agreement with the experimental H2S breakthrough curves.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.