Abstract

The effect of humidity on the vibrational relaxation of O2(v) and N2(v) in a humid-air pulsed corona discharge is studied using a kinetic model. We previously showed that humidity markedly increases the vibration-to-translation (V–T) rate of molecules in a humid-air pulsed corona discharge by measuring O2(v) density (Ono et al 2010 Plasma Sources Sci. Technol. 19 015009). In this paper, we numerically calculate the vibrational kinetics of O2, N2 and H2O to study the reason behind the acceleration of V–T in the presence of humidity. The calculation closely reproduces the measured acceleration of V–T due to humidity, and shows that the increase in the V–T rate is caused by the fast vibration-to-vibration (V–V) processes of O2–H2O and N2–H2O and the subsequent rapid V–T process of H2O–H2O. In addition, it is shown that O atom density is also important in the vibrational kinetics owing to the rapid V–T process of O2–O.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.