Abstract

A simplified, in-line solid-phase extraction and clean-up process is presented for rapid extraction and analysis of steroid estrogens and nonylphenols by gas chromatography with tandem mass spectrometry. Isotope dilution with multiple deuterated standards has been developed, evaluated, and verified using this method against standard addition for the analysis of estrone, estradiol, estriol, ethinylestradiol, and 4-nonylphenols in septic, soil, and groundwater matrices. The accuracy and precision of isotope dilution was comparable to standard addition yet was able to quantify analytes with the use of fewer samples by including [ 2H 4]estradiol, [ 2H 4]ethinylestradiol, [ 2H 4]nonylphenol, and estradiol-17-acetate as internal standards. Specific details and validation of the method are presented as are data showing the occurrence of estrogens and nonylphenols in an on-site wastewater treatment (septic) system with advanced stages of pretreatment and recirculation to an office building for non-potable reuse.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.