Background and Aims: Two dimensional transthoracic echocardiography (2DE) is widely used for detecting congenital heart disease and is possible to obtain precise measurement of Patent ductus arteriosus (PDA) for device selection required for transcatheter closure. Primary aim of the study is to determine whether echocardiographic assessment alone can be used for selection of device for transcatheter closure of PDA.
 Methods: Children with PDA and planned for transcatheter intervention were included in this cross-sectional study of one year. PDA was assessed with 2DE and prediction of device size was made.
 Results: The results were obtained from 107 children. The median age and weight at intervention were 3.8 years (ranging from 6 months to14 years) and 12 kg (ranging from 3.5 to 60 kg). Type A (Conical) PDA was the commonest PDA morphology accounting for 87.8% and 85% in 2DE and angiography respectively. There was no difference (p < 0.05) in the narrowest diameter at pulmonary end measured by 2DE and angiography, however ampulla diameter and ductal length were statistically different (p = 0.95). The predicted size of device by 2DE was discordant (p < 0.05) to the actual device used in a total study population, however when patients with severe pulmonary hypertension, non-type A and larger PDA (narrowest diameter > 6mm) were excluded, the predicted size of device by 2DE was statistically concordant (p = 0.1) to the actual device used in 89 (83%) patients.
 Conclusion: Two dimensional Transthoracic echocardiography alone may be helpful in choosing the device during transcatheter closure of PDA in selective group of patients.

Highlights

  • Patent ductus arteriosus (PDA) is a common congenital heart disease (CHD) in children accounting for ~ 5 – 10 % of all CHDs1

  • The recent advancement in echocardiography with its improved resolution makes it possible to obtain precise measurements for adequate device selection required for transcatheter closure

  • PDA morphology and size were assessed in parasternal short axis (PSAX) view, high parasternal view and suprasternal view

Read more

Summary

Introduction

Patent ductus arteriosus (PDA) is a common congenital heart disease (CHD) in children accounting for ~ 5 – 10 % of all CHDs1. Cardiac catheterization via arterial access, especially in small children weighing less than 10 kg, usually brings minor to major complications like prolong bleeding, groin hematoma and decrease to absent distal pulses. This causes distal perfusion compromise which lead to increase dose of heparin, prolong sedation time, prolong procedural time, prolong hospital stay and increase cost[5,6,7,8]. Two dimensional transthoracic echocardiography (2DE) is widely used for detecting congenital heart disease and is possible to obtain precise measurement of Patent ductus arteriosus (PDA) for device selection required for transcatheter closure.

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.