Abstract

Thyroidectomy is an elective operation performed in an anatomically complex region in which certain structures are responsible for vital functions and special senses. This study aims to compare the effects of two different technical approaches-nerve dissection combined with intraoperative nerve monitoring (IONM) and no nerve identification-on recurrent laryngeal nerve (RLN) damage in total thyroidectomy. One hundred and sixty-one consecutive cases that underwent total thyroidectomy and 322 RLN under risk were evaluated. In group 1 (n = 162), nerve dissection combined with IONM was performed, whereas no RLN identification was performed in group 2 (n = 160). While the duration of operation in group 1 (34.23 ± 12.21min) was statistically shorter than that in group 2 (36.98 ± 16.79min, p = 0.017), there was no significant difference between groups related to RLN palsy (group 1 n = 10, group 2 n = 7). Use of IONM was found only to shorten the duration of operation. According to our presented experience, there is no benefit of IONM-combined routine dissection of RLN during total thyroidectomy on the prevention of RLN palsy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.