Abstract
A homogeneous (AMX) and two heterogeneous (MA-40, MA-41) anion-exchange membranes, as well as a heterogeneous cation-exchange membrane (MK-40), are studied by electronic scanning microscopy, voltammetry, and chronopotentiometry. The presence of conducting and nonconducting regions on the surfaces of heterogeneous membranes is established by means of element analysis. The fraction of conducting regions is found by an image treatment. The surface of the AMX membrane was partially coated with microspots of a paint to make it heterogeneous (AMXheter). Voltammetric and chronopotentiometric measurements for AMX, AMXheter, and MA-41 membranes in NaCl solutions are carried out and the pH changes in the solution layers adjoining to these membranes are recorded. Analysis of obtained results shows that the concentration polarization of studied membranes characterized by the potential drop and the rate of water dissociation at the interface is mainly governed by the properties of their surfaces. It is found that the local limiting current density through conducting regions of a heterogeneous membrane is several times higher than the average limiting current through a homogeneous membrane.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.