Abstract
As a highly efficient cryogenic heat transfer device, cryogenic loop heat pipe (CLHP) promises great application potential in the thermal control of future space infrared detection system. In this work, a CLHP using methane as working fluid operating at 100–190 K was developed, and its thermal performance including the supercritical startup, heat transport capacity under different heat sink, power cycling characteristics, temperature hysteresis phenomenon and thermal resistance variation, was experimentally investigated. Experimental results showed that the CLHP could successfully realize the supercritical startup under various auxiliary heat loads applied to secondary evaporator, reach a various heat transfer capacity under different heat sink temperature over a 0.6 m distance, and manifest good response characteristics to the cycle of heat load applied to the primary evaporator. The temperature hysteresis phenomenon was detected and thermal resistance of the CLHP varied with increasing heat load applied to the primary evaporator, but not the same with that in heat load reverse motion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.