Abstract
We have conducted a study of the elimination kinetics of fluoride ions by a log linear regression analysis of plasma levels obtained during a bicarbonate hemodialysis session, with a dialyzer in polymercaprin for six patients with chronic renal failure. Using plasma fluoride levels of 35 patients studied for 20 months, we have validated these kinetics for hemodialysis with sodium bicarbonate, acetate-free biofiltration, hemodiafiltration with low flow rate and other dialyzers. Our results show that the decrease in plasma fluoride levels is statistically significant only after the first hour, and the fall reaches approximately 30% after a 4 h dialysis session. We propose that post-dialysis measurements of plasma fluoride are now not necessary if levels before dialysis are known.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.