Abstract

In this study, modeling and thermodynamic analysis of the combined double flash geothermal cycle generation was conducted using zeotropic fluid as the working fluid in the Organic Rankine Cycle (ORC). The analysis was performed based on the first and second laws of thermodynamics. Hexane, cyclohexane, isohexane, R245fa, and R236ea exhibit good performance at higher temperatures. In this study, three fluids—hexane, cyclohexane, and isohexane—were used. First, the model results for the pure fluids were compared with those of previous studies. Then, the important parameters of the cycle, including the efficiency of the first law of thermodynamics, the efficiency of the second law of thermodynamics, net productive power, and the amount of exergy destruction caused by changing the mass fraction of the refrigerant for the zeotropic fluids (investigated for the whole cycle and ORC), were obtained and compared.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.