Abstract

Cavitation is a well-known phenomenon that causes performance losses in all kinds of hydraulic machinery, including automotive water pumps. The present study uses a coolant flow test rig to investigate cavitation in water pumps. The coolant flow rate was measured for various coolant temperatures and compositions. This study validates that cavitation occurs during the coolant warm-up period, in which coolant temperature is typically below 80°C. Cavitation was also related to a drop in the water pump inlet pressure and driving torque. Based on the results from this study, it can be concluded that cavitation is affected by coolant temperature, engine speed, and coolant composition. Furthermore, it is found that the use of an electric water pump is effective for minimizing the pressure drop and driving loss of the pump. Copyright © 2008 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.