Abstract

The operation of centrifugal pumps can generate instabilities and pressure pulsations that may be detrimental to the integrity and performance of the pump. In the present study a numerical investigation of the time variation of pressure within a complete centrifugal pump was undertaken. A range of parameters and three flow rates were investigated and the pulsations were extracted at 15 different locations covering important pump regions. The transient flow results compared reasonably with experimental data obtained in a limited experimental survey and clearly indicated the pump locations experiencing the largest pulsation levels. It was also noted that monitoring pulsations at the top dead centre of the pump volute casing would provide a better indication of internal pump pulsations than monitoring at the discharge.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.