Abstract

Global energy demand continues to increase, and the construction sector has a fundamental role in this subject by achieving high hygrothermal performance. This study evaluates the impact of construction quality defects on the hygrothermal performance and airtightness of a lightweight-structure wooden envelope system. Four typical defects were evaluated, orifices in the weather barrier, staples in the vapor barrier, nails diverted to external insulation, and separated structural elements. The results showed that all the defects decreased the hygrothermal performance of the wood-frame envelope assessed. Structural separation and staples over the vapor barrier caused the most significant negative variations, increasing heat loss, the probability of interstitial condensation and air infiltration considerably.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.