Abstract

The FMC Westvaco Trona Mine is located near Green River, Wyoming and has an annual production of 4.5 M tons. The underground mine has three active development panels and one longwall panel. The mining horizon is about 500 m below surface and strata liberates methane. Three surface-based blowing fans provide ventilation air. A ventilation survey and subsequent analysis was undertaken and a simulation model developed. Air heating during winter is essential to prevent freezing of pipelines and to lesser degree, for miner comfort. Air at all three intake shafts is heated using gas-fired heat exchangers.A strata heat study was conducted in one of the active panels to determine rock attributes. Tests included in-situ measurements of rock thermal conductivity and geothermal gradient. Ventsim ventilation software was used to aid the heat and contaminant simulation study. An exercise was also undertaken to gain some understanding of methane contaminant levels throughout the mine. It was further used to determine an adequate surface intake air heating rate and consequently the minimum natural gas consumption needed for winter intake air heating at the mine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.