Abstract

The success of geological storage of carbon dioxide (CO2) in depleted oil and gas reservoirs relies among other aspects on the efficiency of CO2 injection, especially in the near-wellbore area where flow rates are high. CO2 hydrates pressure/temperature equilibrium conditions may be reached in this zone due to cooling associated with the Joule–Thomson effect; such CO2 hydrate formation may lead to strong injectivity loss and impair drastically the onsite well operations. In this study, cyclopentane hydrates (CPH) were employed as CO2 hydrate proxy (i.e. formation at atmospheric pressure) to mimic CO2 hydrate formation at higher pressure. In this study, the nucleation and growth processes were determined using a droplet-based in-house-microfluidic device. The generation of water droplets in cyclopentane liquid using the co-flow method was achieved. Trains of identical water droplets were stored in a serpentine channel. Each isolated droplet in this channel serves as a separate reactor. The temperature was controlled using a Peltier module to initiate hydrate nucleation at low temperatures. The isolated droplets provided the opportunity to statistically analyze the kinetic behaviors by varying key parameters, such as thermal history and water salinity. Detection of the onset of crystallization in water droplets over time and temperature allowed us to plot conversion curves based on imposed parameters. The effect of thermal history and dissociation temperature was first compared using pure water. This study marks the initial investigation into how NaCl influences CPH formation in microfluidic devices, focusing on isolated water droplets within serpentine tubes. The progression of ice nucleation, ice melting, the onset of CPH crystallization, CPH growth, and CPH dissociation are illustrated in water droplets exposed to changing temperatures. The addition of NaCl in the water during the procedure exhibited a noteworthy impact on CPH formations. With the same temperature profile, salt concentration delays nucleation (thermodynamic effect) and slows down growth. Our findings suggest that higher subcooling accelerates nucleation and growth rates. Initial lateral growth rates ranged from 4.22 μm/s to 2.14 μm/s, with a subcooling of 4.2 °C observed between 2 and 7 min for a pure water droplet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.