Abstract

Abstract In order to more accurately evaluate the transition process characteristics of pump turbine in pumped storage power station, this paper summarized a systematic inversion calculation and analysis method. Using this inversion calculation method, this paper calculated and analyzed the pressure changes for different load conditions of the same unit, similar conditions of other units in the same hydraulic unit and similar conditions of similar units in other hydraulic units based on the actual measured data of load rejecting test in a pumped storage power station. The inversion calculation results are in good agreement with the experimental measured data, which proves that it is feasible to predict the transient pressure by using this method for inversion calculation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.