Abstract

One of the important tasks of modern flow measurement is to measure the flow rate and the amount of wet gas. This task becomes especially important when there is a need to obtain information about the amount of dry gas at the production facilities. The paper presents the principle of operation and structure of the invariant wet gas measurement system. The work of the invariant flow measurement system is based on the application of the principle of multichanneling and the method of partial flow measurement. Coriolis flowmeters are used as the main elements of the system. The proposed measurement system does not imply the use for gases with abundant droplet moisture. The authors propose a method of verification of the measurement system, which is currently limited by the measurement error of moisture in the gas equal to 5%. The article also provides information on the results of the test of the system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.