Abstract

We have assessed in normal subjects the validity of using hand heating to obtain "arterialized" venous blood by biochemical comparison of results for "arterialized" venous and true arterial (radial artery) blood samples. The heating regimen involved placing one hand in an air-heated box at 45-50 degrees C for 45 min. This method produced blood that was "arterialized" for lactate, PCO2, HbO2, and Hb but not for ammonia or PO2; it had no effect on determinations of pyruvate or glucose in plasma. Despite using a lower air temperature than previous workers, we observed thermal injury in one volunteer. Further, there was considerable between-subject variation in the effect of hand heating on blood gases. This suggests that blood gases should be measured in the "arterialized" samples at regular intervals from the start of hand heating in each patient to determine whether maximal "arterialization" has been achieved, to avoid making misleading biochemical measurements. Given the wide range in degree of observed "arterialization," we question the validity of this method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.