Abstract

AbstractTo date, the AC dielectric breakdown strength of polyimide (PI) films, as for most polymers, is understood to follow a thickness dependency with a measured power law exponent, n ≈ 0.5. However, this work experimentally demonstrates that the AC dielectric strength of PI films is quasi‐thickness independent. Evidence is presented showing that the thickness dependency described in the literature can be explained by an extrinsic failure mode, driven by partial discharges occurring at the dielectric‐oil‐electrode triple point. Triple points can be avoided by electrode encapsulation, which subsequently recovers a purely intrinsic failure mode for PI films over a large thickness range. Consequently, the AC dielectric strength of thick PI films is intrinsic and quasi‐thickness independent, at least for film thickness up to 60 µm. For the first time, a “theoretical” AC breakdown field for PI films is reported as ≈520 Vrms µm−1. Finally, the highest experimental breakdown field values are obtained here with 505 Vrms µm−1 and 705 Vµm−1 under AC and DC fields, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.