Abstract

Background In cardiovascular research, there is an increasing interest in high-field MRI to characterize cardiac anatomy and function in small rodents. However, data on reproducibility of the method are scarce. Our aim was to evaluate the intra-observer, inter-experiment and inter-observer variability of left ventricular (LV) mass and volumes measurements in mice using an 11.7T MRI scanner. Methods Seven 10 weeks-old C57Bl6J male mice were studied, including 4 animals with a surgical transverse aortic constriction in order to produce cardiac hypertrophy. 3 were sham (control) mice. During the entire procedure, animals were anaesthetized with Isoflurane 1-3%, in a temperature-controlled setting. Scan were retrospectively gated for electrocardiogram (ECG) and respiration. Imaging was performed on a 11.7 Tesla Bruker MR scanner. Cardiac scout images were obtained in the conventional planes with a tripilot sequence. A 2D cine FLASH sequence was applied to acquire a set of 7 contiguous short axis images covering the entire ventricles, perpendicular to the LV long axis. One day after the procedure, mice were scanned again under the same conditions. The LV systolic function was assessed from each stack of images by tracing epicardial and endocardial borders, including papillary muscles, on the Segment software (Medviso, Sweden). End-diastolic (EDV), end-systolic (ESV) and stroke volume (SV) were determined (µl). LV ejection fraction (EF, in %) and LV mass (mg) were subsequently deduced. One stack of images was analyzed twice by the same person, and once by an independent observer. Results Accurate quantitative data were obtained in all animals. The Table 1 lists the mean ± SD values and the Bland-Altman and Pearson analysis results. The best reproducibility was obtained for the measurements of LV mass and EDV, with a coefficient of variability (Cov) between 1.70 and 12%. More variation was found in ESV measurement (CoV 1-70-22.40%). Results for SV and EF were the less reproducible, with a CoV between 14.52 and 31.45%. The Pearson correlation coefficient indicates good correlation between all methods for all parameters (r square between 0.81 and 0.99), except for the SV, particularly in terms of inter-experiment reproducibility (r square =0.03). Conclusions In our hands, reproducibility was excellent for LV mass and EDV, good for ESV and EF to al esser extent, and more limited for the stroke volume, with a bad inter-observer correlation. This highlights the need to interpret our results by taking into account these limitations, focusing on more reproducible parameters when interpreting data.

Highlights

  • In cardiovascular research, there is an increasing interest in high-field MRI to characterize cardiac anatomy and function in small rodents

  • A 2D cine FLASH sequence was applied to acquire a set of 7 contiguous short axis images covering the entire ventricles, perpendicular to the left ventricular (LV) long axis

  • Accurate quantitative data were obtained in all animals

Read more

Summary

Open Access

Intra-observer, inter-experiment and inter-observer variability of left ventricular volumes and mass measurements in mice using an 11.7 Tesla MRI. Laetitia Vanhoutte1,2*, Olivier Feron, Jean-Luc Balligand, Bernard Gallez, Hrag Esfahani, Stéphane Moniotte. From 16th Annual SCMR Scientific Sessions San Francisco, CA, USA. From 16th Annual SCMR Scientific Sessions San Francisco, CA, USA. 31 January - 3 February 2013

Background
Methods
Results
Conclusions
Interobserver variability
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.