Abstract
Respiration is a highly dynamic signal that influences voluntary behaviors including odor sampling and entrains rhythmic activity in the brain. Many techniques exist to record respiration with each exhibiting strengths and drawbacks given the ultimate goals of the respiration recording. Intranasal cannula implantation, coupled with pressure sensor recording, allows for temporal precision and detailed feature extraction of the respiratory waveform. Here we describe the implantation process and necessary recording equipment to effectively conduct intranasal pressure recording of respiration. This is an ideal method for understanding the dynamics of odor sampling in conjunction with olfactory sensory transmission.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.