Percutaneous vertebroplasty is a relatively easy and minimally invasive procedure used in treating vertebral fractures. However, the procedure has many complications, one of which is bone cement leakage, which happens frequently. Leakage to the paravertebral venous system, in particular, may lead to especially devastating consequences. Here we report a case of a 65-year-old male patient with an intracardiac foreign body (bone cement) that generated a perforation on the right ventricle, and result in hemopericardium after percutaneous vertebroplasty. We performed open heart surgery to remove the foreign body.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Korean Journal of Thoracic and Cardiovascular Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.