Abstract

Fouling is one of the most pressing limitations during operation of membrane bioreactors, as it increases operating costs and is the cause of short membrane lifespans. Conducting effective physical cleanings is thus essential for keeping membrane operation above viable performance limits. The nature of organic foulants present in the sludge and the membrane properties are among the most influential factors determining fouling development and thus, efficiency of fouling mitigation approaches. The role of other factors like sludge viscosity on fouling is still unclear, given that contradictory effects have been reported in the literature. In the present study we use a new research approach by which the complex interplay between fouling type, levels of permeate flux, membrane material and feed properties is analyzed, and the influence of these factors on critical flux and membrane permeability is evaluated. A variety of systems including activated sludge and model solutions with distinct rheological behavior has been investigated for two membranes differing in pore size distribution. We present a novel method for assessing the efficiency of fouling removal by backwash and compare it with the efficiency achieved by means of relaxation. Results obtained have proven that backwash delays development of critical fouling as compared with relaxation and reduces fouling irreversibility regardless of fluid rheology. It was shown that backwash is especially effective for membranes for which internal fouling is the main cause of loss in permeability. Nonetheless, we found out that for membranes with tight pores, both relaxation and backwash are equally effective. The critical flux decreases significantly for high-viscosity fluids, such as activated sludge. This effect is mainly caused by an intensified concentration polarization at the feed side rather than by internal fouling events. However, membrane permeability has been proven to rely more on the permeate viscosity than on the feed viscosity: poor rejection of organic fractions showcasing high viscosity causes an acute decline in membrane permeability as a consequence of increased shear stress inside the membrane pores.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.