Abstract
Stabilizing the aorto-ventricular junction is integral in aortic valve repair. We report our technique of internal circular suture annuloplasty. We used a continuous horizontal mattress suture of a single thick expanded polytetrafluoroethylene suture (CV-3). We put 4 stitches per sinus, so the suture was below the cusp attachment line at the nadirs and passed through the interleaflet triangle at the upper aorto-ventricular junction level. The suture was reinforced with pericardial pledgets on both sides of each commissure. We used this technique in 12 patients. The diameter of aorto-ventricular junction was reduced from 25 ± 2mm to 22 ± 1mm (n = 11) and was 22 ± 1mm at the latest follow-up (4-74months, median 41, n = 10). In 2 patients with large aorto-ventricular junction (27mm or more), expected annular reduction was not achieved. Our modified technique is simple and seems durable. It may be useful for mild annular dilatation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.