Abstract

A Michelson interferometry apparatus was used for measurement of the displacement of the buccal cusps of premolars after restoration of MOD preparations with composites. The effects of composite type, cavity size, and hydration conditions were examined. Interferometry permitted real-time measurement of cusp movement as it occurred. Contraction occurred very rapidly, about 1/3 of the 60-minute amount within the two-minute period of exposure to the curing light. Cusp movement was smooth rather than interrupted, indicating lack of microfracturing at deformations of 11-46 microns. Contraction, 0.94% for Heliomolar and 1.2% for P-50, was similar to the linear polymerization shrinkage of the resins. Less cusp movement occurred in small cavities than in large cavities. Hydrated teeth had less cusp movement than dehydrated teeth.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.