Abstract

The distribution variation and correlation of envelope interference factor (EIF) of the base torsion responses for principal building were studied by applying the rigid model wind tunnel test. The influence factor including different breadth ratio (Br=0.4, 0.6, 0.8, 1.0, 1.2 and 1.4), height ratio (Hr=0.8, 1.0, 1.2 and 1.4), reduced velocity and approaching turbulence intensity were considered. Furthermore, the mechanism and occurrence condition of wake vortex-excited resonance were also studied. Results showed that the maximum value of EIF was 1.9 when vortex-excited resonance failed to happen. The correlation coefficient of EIF between Br=0.8 and Br=1.0 was 90.2%. Vortex-excited torsion resonance which induced from wake of interfering building occurred when Br=0.4, and the maximum value of EIF reached up to 2.98. With increased Hr, the value of EIF increased. Good correlation was shown among different height ratios. For breadth ratios range from 0.3 to 0.5, it was suggested the reduced velocity should be out of the range of 3.33–5.56 to avoid occurring vortex-excited torsion resonance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.