Abstract
Accurate determination of interfacial polarization resistance is essential to characterization of solid-state electrochemical systems based on thin-film electrolytes or membranes. In this study, three methods have been used to determine the interfacial resistance of a composite membrane consisting of 40 vol.% Ni and 60 vol.% BaY x Ce 1− x O 3. The interfacial resistances determined from the dependence of hydrogen permeation rate on membrane thickness were similar to those obtained from a combination of gas permeation with impedance spectroscopy (IS), implying that both approaches are applicable to the composite membrane. Results also indicate that the interfacial resistances are much greater than the bulk resistances under the conditions studied. Further improvement of the hydrogen permeation rate thus depends on reducing the interfacial polarization resistance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.