Abstract

Abstract Thin polyurethane films, having low adhesion to dried protein, were developed as candidate materials for non-adhesive surgical dressings. In order to model wound-adhesion, gelatine was cast from solution on to the film and allowed to dry. The film was peeled from the gelatine at 180° peel angle, and the peel force measured as a function of the temperature of test. The dynamic mechanical properties of the films were measured over the range −90°C to 110°C and values of tan δ were determined at the temperatures employed for peeling. Thus, a correlation was obtained between peeling energy and tan δ for each of eight films. The generalised theory of fracture mechanics states that the adhesive failure energy is given by the product of an interfacial energy term and a “loss function” involving the hysteresis ratio of the material. If the strains are small the hysteresis ratio is proportional to tan δ. The experimental results show excellent agreement with the theory, but the interfacial term turns out t...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.