Abstract

This paper addresses the intercalibration of the infrared channels 7∼16 of Advanced Himawari-8 Imager (AHI8) against the hyperspectral channels of Infrared Atmospheric Sounding Interferometer (IASI) on Metop-B using the hyperspectral convolution method. Matching measurements in July of 2016 were collected over a tropical area (100° E∼180 ° E, 10 ° S∼ 10 ° N) with collocation, absolute observation time difference of less than 5 minutes, and |cosθ 1 /cosθ 2 -1| of less than 0.015, where θ 1 and θ 2 are, respectively, AHI8 and IASI/Metop-B viewing zenith angles. The results show that the AHI8 measurements are highly linearly related to the convolved IASI hyperspectral measurements, and intercalibration coefficients are obtained through linear regression on the matching measurements. Against the IASI hyperspectral channels, the in-orbit calibration biases in AHI8 infrared channels 7∼16 are, 0.09, −0.11, −0.16, −0.04, −0.03, −0.19, 0.07, 0.10, −0.02 and 0.16 K, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.