Abstract

The process of interaction between the chilled drain pipe oxidizer tank with atmospheric air. The conditions when drain- pipes, depending on ambient parameters (temperature, relative humidity). Using modeling package SolidWorks Flow Simulation software processes carried out: a) the expiration of the steam-gas mixture through the drainage and pressure relief valve and drain pipe; b) contacting with chilled air drainage pipe. It is shown that a) during the expiration of the gas mixture the drain pipe cools; b) when closing the safety valve, drainage atmospheric air enters into the drainage pipe, and water vapor condenses and freezes, which can lead to the blockage of the drainage pipe and the explosion of the propellant tank. Recommendations to prevent freezing of the drain pipe.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.