Abstract
The paper concerns the problems associated with the generation and measurement of vacuum in small-volume microelectromechanical (MEMS) devices. A concept of equipping vacuum MEMS with miniature vacuum pump and gauge has been presented. The ion-sorption vacuum micropump developed by the authors has been integrated with two “external” miniature pressure sensors: a specially developed miniature Bayard-Alpert gauge and a MEMS-type Pirani sensor. The pressure during the pumping process was in-situ measured and co-work of vacuum micropump and sensors has been investigated. The experimental results confirmed good pumping properties of the micropump, but indicated that the work of micropump significantly affects the operation of vacuum sensors and vice versa.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.